afm:facilities
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| afm:facilities [2007/04/20 17:01] – galli | afm:facilities [2019/02/14 17:27] (current) – galli | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| + | ====== LION SPM User Facility ====== | ||
| + | |||
| + | |||
| + | ===== JPK NW3-US ===== | ||
| + | |||
| + | JPK Nanowizard 3 Ultra Speed AFM/STM. Located in HL 702, in the middle, against the cupboard.\\ | ||
| + | Fast scan operation, closed loop, motorized stage, large samples and nanolithography. | ||
| + | Several accessories (heating/ | ||
| + | |||
| + | {{afm: | ||
| + | |||
| + | ===== JPK NW4 (shared with LIC) ===== | ||
| + | |||
| + | JPK Nanowizard 4 Ultra Speed AFM/STM. Located in HL 702, on the left close to the wall. Manual precision stage. Several accessories of the NW3 are compatible with this AFM. Scan range: x,y=100 micron, Z=15 micron.\\ | ||
| + | |||
| + | |||
| + | {{afm: | ||
| + | |||
| + | |||
| + | ===== Bruker MM-NS3 ===== | ||
| + | |||
| + | Multimode 5 AFM/STM equipped with controller Nanoscope IIIa. Located in HL 701, immediately on the left.\\ | ||
| + | |||
| + | {{afm: | ||
| + | |||
| + | |||
| + | ===== Bruker MM-NS5 ===== | ||
| + | |||
| + | Multimode 8 AFM/STM (Bruker) with controller Nanoscope V. Located in HL 702, on the left, close to the entrance.\\ | ||
| + | |||
| + | |||
| + | ===== Development SPM ===== | ||
| + | |||
| + | Open Source SPM, Multimode microscope or home built STMs controlled with Open Source SoftdB digital controller. Located in HL 701, in the front, close to the window.\\ | ||
| + | |||
| + | |||
| + | {{afm: | ||
| + | |||
| + | |||
| + | ===== Available Bruker scanners ===== | ||
| + | |||
| + | ^Scanner Type^ Number of available scanners^ Z-Range^XY-range^ | ||
| + | |4837 EV| |2.5μm |10μm x 10μm | | ||
| + | |4645 EV| |2.5μm |10μm x 10μm | | ||
| + | |1461 G| | | | | ||
| + | |5192 JV| |5μm |125μm x 125μm| | ||
| + | |177 A| | 0.4μm|0.4μm x 0.4μm| | ||
| + | |||
| + | |||
| + | ===== Available Bruker tip holders ===== | ||
| + | |||
| + | ^Name^ Number ^ What for ^ | ||
| + | |TM air | 3 (a,b,c) |tapping mode air| | ||
| + | |CM air | 1 |contact mode air| | ||
| + | |EFM| 1 |electric force microscopy| | ||
| + | |CM Fluid | 2 (1,2)| contact mode in liquid| | ||
| + | |TM fluid | 2 (1, Raoul' | ||
| + | |CSAFM| 1 | current sensing AFM| | ||
| + | |||
| + | ===== Available JPK Accessories ===== | ||
| + | |||
| + | * Heating/ | ||
| + | * Heating stage: up to 300C | ||
| + | * EC cell (M. Koper -LIC) | ||
| + | * STM module | ||
| + | * CS-AFM module | ||
| + | |||
| + | |||
| + | |||
| + | |||