 +Link to the manual: {{wiki:karlsuss_ma45_manual.pdf |manual}}
 +
 ====== Prepare your sample ====== ====== Prepare your sample ======
   - clean your sample   - clean your sample
Line 7: Line 9:
  
 ====== start ====== ====== start ======
-  - turn on the lamp+  - turn on the lamp using instructions on the machine
   - choose a mask   - choose a mask
   - if you use a piece of Si, put the Cu holder on the plate and align one of the holes at 3 o'clock. use 2 useless pieces of Si on the other holes of the Cu holder and your sample on the aligned hole.   - if you use a piece of Si, put the Cu holder on the plate and align one of the holes at 3 o'clock. use 2 useless pieces of Si on the other holes of the Cu holder and your sample on the aligned hole.
Line 17: Line 19:
 warning opd4262 is a strong base, when using this you are required to wear eye protection. To depose of this developer you have to put it in the acids bin (can be found under the wetbench with a black label). warning opd4262 is a strong base, when using this you are required to wear eye protection. To depose of this developer you have to put it in the acids bin (can be found under the wetbench with a black label).
  
-1. Fill a glass with developer (OPD4262) and one with demiwater. +  - Fill a small glass with developer (OPD4262) and one with demiwater. 
-2. Develop for 1 min. +  Develop for 1 min. 
-3. put in demiwater at least 2 min +  put in demiwater at least 2 min 
-4. Dry with N2 and be careful not to damage your structure.+  Dry with N2 and be careful not to damage your structure.
  
  
 ====== When you're done ====== ====== When you're done ======
-1. Switch off the lamp of the mask aligner and the mask aligner itself. +  - Switch off the lamp of the mask aligner and the mask aligner itself. 
-2. Switch off the hot plate. +  Switch off the hot plate. 
-3. Clean the spin coater. +  Clean the spin coater. 
-4. Clean up the glasses you used. +  Clean up the glasses you used. 
-5. Fill in the log book. +  Fill in the log book.
  
  
 +If you want a new mask contact the technicians (609a)
  