| ====== Safety ====== | ====== Safety ====== | ||
| - | Everyone working in the NanoLab should have received the LION safety regulations and have read them thoroughly. \\ ([[http://www.physics.leidenuniv.nl/ | + | Everyone working in the NanoLab should have received the LION safety regulations and have read them thoroughly. \\ ([https://www.science.leidenuniv.nl/ |
| {{wiki: | {{wiki: | ||
| Line 19: | Line 19: | ||
| ===== Chemicals ===== | ===== Chemicals ===== | ||
| + | When you want to start working with chemicals, read the following document: {{ :: | ||
| + | |||
| Be //very// careful to avoid eye contact with all chemicals. If you get strong alkalies like resist developers in your eye your vision will almost certainly be damaged! Avoid all skin contact with anorganic chemicals (acids and bases) and avoid their vapours by working in a fume hood. Avoid skin contact and especially inhalation of organic chemicals by working in a downflow bench, cleanbench or fumehood. | Be //very// careful to avoid eye contact with all chemicals. If you get strong alkalies like resist developers in your eye your vision will almost certainly be damaged! Avoid all skin contact with anorganic chemicals (acids and bases) and avoid their vapours by working in a fume hood. Avoid skin contact and especially inhalation of organic chemicals by working in a downflow bench, cleanbench or fumehood. | ||
| - | Always hold a bottle with 2 hands and never even think of just holding the cap. Some organics require evacuation of the building if you drop a bottle! If a bottle breaks and chemicals are spilled there may be an explosion danger. Walk to the 3 button wall panel and switch all 3 buttons off so that the room is completely shut down, then warn Ruud Hendrikx | + | Always hold a bottle with 2 hands and never even think of just holding the cap. Some organics require evacuation of the building if you drop a bottle! If a bottle breaks and chemicals are spilled there may be an explosion danger. Walk to the 3 button wall panel and switch all 3 buttons off so that the room is completely shut down, then warn Daan Boltje |
| Each cleanbench / downflow bench / fume hood has an eye shower on top. Eye showers are single use! Do not twist the cap out of curiosity, once opened they cannot be closed and must be discarded. If you get covered by chemicals there are showers in the hall on each side of the floor. | Each cleanbench / downflow bench / fume hood has an eye shower on top. Eye showers are single use! Do not twist the cap out of curiosity, once opened they cannot be closed and must be discarded. If you get covered by chemicals there are showers in the hall on each side of the floor. | ||
| Line 45: | Line 47: | ||
| * Xylene | * Xylene | ||
| * HCL | * HCL | ||
| - | * HNO<SUB>3</SUB> | + | * HNO<sub>3</sub> |
| * HF | * HF | ||
| - | * H<SUB>3</SUB>PO<SUB>4</SUB> | + | * H<sub>3</sub>PO<sub>4</sub> |
| You can look up the MSDS at http:// | You can look up the MSDS at http:// | ||
| Line 66: | Line 68: | ||
| http:// | http:// | ||
| - | Both types will protect your sample from your fingerprints; | + | Both types will protect your sample from your fingerprints; |
| + | |||
| + | ==== Which tweezers to use? ==== | ||
| + | The chemical compatibility of plastic tweezers {{: | ||
| + | |||
| + | |||
| + | * CF = PA66/CF30 polyamide 66 reinforced with 30 wt% carbon fibre | ||
| + | * CP = PEEK/CF30 polyetheretherketone reinforced with 30wt% carbon fibre | ||
| + | * LC = PPS/GF30 polyphenylene sulphide reinforced with 30wt% glass fibre | ||
| + | * LP = PPS/GF30 polyphenylene sulphide reinforced with 30wt% glass fibre | ||
| + | |||
| + | |||
| + | |||
| + | |||
| Line 101: | Line 117: | ||
| The cleanbenches and tables in the labs are not sample storage spaces. If samples are found there they will be immediately removed and stay for a month or so in the ' | The cleanbenches and tables in the labs are not sample storage spaces. If samples are found there they will be immediately removed and stay for a month or so in the ' | ||
| + | |||
| + | A quick overview of DO's and DONT' | ||
| + | * DO refill the wash bottles when they are almost empty (10%) | ||
| + | * DO empty the 1 liter waste bottles (wetbench cleanroom, cross flow sputter lab) in the big waste container (red label) | ||
| + | * DO replace acetone/ | ||
| + | * DO inform me when we are running low (10%) on consumables (developers, | ||
| + | * DO NOT put empty bottles back on the shelf! | ||
| + | * DO NOT think it is the responsibility of someone else to refill or inform me. These things do not magically happen by dwarfs in the late evening! | ||
| ===== Glasswork ===== | ===== Glasswork ===== | ||
| Line 140: | Line 164: | ||
| Place washbottles and other items the way that is indicated on the cleanbench plan. | Place washbottles and other items the way that is indicated on the cleanbench plan. | ||
| Clean up and dry the surface after use (much better than you clean the sink at home) | Clean up and dry the surface after use (much better than you clean the sink at home) | ||
| - | |||
| ===== Clean room 612 ===== | ===== Clean room 612 ===== | ||
| Never use the spin coater without aluminum foil inside. Clean away resist spills immediately. | Never use the spin coater without aluminum foil inside. Clean away resist spills immediately. | ||
| Clean up the clean benches after use (much better than you clean the sink at home) | Clean up the clean benches after use (much better than you clean the sink at home) | ||
| + | |||
| + | === Phone number === | ||
| + | 6203 | ||
| ===== Chemistry lab 607 ===== | ===== Chemistry lab 607 ===== | ||